Stainless Steel Coil Tube for Fan Coil Unit (FCU) HVAC Systems

1. Product Overview

The Stainless Steel Coil Tube (Coiltube) manufactured by Wenzhou Jixing Metal Materials Co., Ltd. is a precision-engineered tubular component specifically designed for integration into Fan Coil Unit (FCU) air conditioning systems. As a critical heat exchange element, the coil tube facilitates efficient thermal transfer between the refrigerant or heating medium and the ambient air stream, thereby ensuring optimal temperature regulation and humidity control within commercial and residential HVAC environments.

Rooted in the design methodology outlined in the technical paper "Discussion on the Design and Calculation Methods of Fan Coil Unit Air Conditioning Systems", this product embodies rigorous engineering principles governing airflow dynamics, heat transfer coefficients, and pressure drop calculations essential for high-performance HVAC system design.

2. Material & Properties

2.1 Base Material Composition

2.2 Key Mechanical Properties

2.3 Corrosion Resistance

The austenitic microstructure provides exceptional resistance to pitting corrosion, crevice corrosion, and intergranular corrosion, making the coil tube suitable for environments with high humidity, acidic condensate, or chlorinated cooling water. The AISI 316 grade offers additional chloride resistance due to the presence of molybdenum.

3. Technical Specifications

Parameter Specification Standard / Tolerance
Outer Diameter (OD) Φ 6.0 mm / Φ 8.0 mm / Φ 9.52 mm / Φ 12.0 mm ±0.1 mm
Wall Thickness 0.3 mm / 0.4 mm / 0.5 mm / 0.6 mm ±0.03 mm
Coil Pitch 12 mm – 25 mm (adjustable) ±0.5 mm
Coil Diameter Φ 150 mm – Φ 600 mm ±1.0 mm
Tube Length per Coil 0.5 m – 6.0 m (customizable) ±5 mm
Surface Finish Mirror Polish (Ra ≤ 0.4 μm) / Brushed Finish (Ra ≤ 1.6 μm) ASTM A269
End Connection Type Flared / Threaded (G1/4, G1/2, G3/4) / Soldered / Brazed ASME B1.20.1
Pressure Rating ≤ 2.5 MPa (operating), ≤ 4.0 MPa (hydrostatic test) EN 10217-7
Refrigerant Compatibility R-22, R-32, R-410A, R-134a, R-407C, R-404A, R-507 ASHRAE Standard 34
Heat Transfer Coefficient 150 – 350 W/(m²·K) (depending on configuration) ASHRAE Handbook
Water Side Flow Rate 0.2 – 2.0 L/s (per circuit) EN 12830
Design Airflow Capacity 50 – 500 m³/h (per unit) ASHRAE 15

4. Manufacturing Process

4.1 Seamless Tube Forming

Raw stainless steel wire rod undergoes hot-rolling followed by cold-drawing to produce seamless tubes with uniform wall thickness and precise dimensional tolerances. The cold-drawing process enhances grain structure refinement, resulting in improved mechanical properties and surface integrity.

4.2 Coil Winding

The drawn tubes are wound into precise helical coils using CNC-controlled coiling machines. The winding process maintains consistent pitch, avoids kinking or ovalization, and ensures the tube retains its circular cross-section throughout the coil geometry. Tension control systems prevent residual stress accumulation.

4.3 Heat Treatment & Annealing

4.4 Surface Treatment

Post-manufacturing surface finishing includes electrolytic pickling and passivation to remove decarburized layers and oxide scale, establishing a protective chromium oxide film. Mirror-polished variants undergo multi-stage mechanical polishing followed by chemical passivation per ASTM A967.

4.5 End Finishing & Assembly

Tube ends are deburred, chamfered, and fitted with appropriate connection hardware (flanges, threaded fittings, or brazed joints). Each coil assembly is pressure-tested at 1.5× the maximum operating pressure for a minimum duration of 30 minutes to verify leak-tightness.

5. Applications

6. Quality Certifications & Compliance

7. Unique Selling Points

8. Design Calculation Methodology Reference

The thermal and hydraulic performance of this coil tube is validated against the design calculation framework described in "Discussion on the Design and Calculation Methods of Fan Coil Unit Air Conditioning Systems." Key parameters include:

  • Heat Transfer Rate (Q): Calculated based on enthalpy difference across the coil face, mass flow rate of air, and coil effectiveness
  • Surface Heat Transfer Coefficient (h_o): Determined using empirical correlations for finned-tube heat exchangers under cross-flow conditions
  • Pressure Drop (ΔP): Computed using Darcy-Weisbach equation with appropriate friction factor for turbulent flow in the coil passages
  • Approach Temperature: Optimized to minimize the temperature difference between the leaving air and the refrigerant/cooling water temperature

9. Ordering Information

Wenzhou Jixing Metal Materials Co., Ltd. offers both standard catalog products and custom-engineered coil tube solutions. Customers are encouraged to provide system-level design parameters including target cooling/heating capacity, refrigerant type, operating pressure, and environmental conditions to receive a tailored quotation and technical proposal.