Stainless Steel Coil Tube for HVAC Fan Coil Unit Applications

Product Overview

Wenzhou Jixing Metal Materials Co., Ltd (Product No. 1589) manufactures precision stainless steel coil tubes (Coil Tube) engineered specifically for use in HVAC (Heating, Ventilation, and Air Conditioning) fan coil unit assemblies. These coil tubes serve as the primary heat exchange media within fan coil systems, facilitating efficient thermal transfer between circulating water/air and the ambient environment. The product line addresses the critical engineering requirements of condensate management, thermal performance optimization, and long-term corrosion resistance in demanding indoor air quality environments.

The coil tube product family is designed with particular attention to the interplay between tube geometry, condensate generation rates, and condensate drain pipe sizing — a subject of extensive engineering study documented in the technical literature on fan coil unit performance. Proper coil tube specification directly influences condensate volume calculations and the appropriate selection of condensate drain pipe diameters, ensuring system reliability and preventing water damage in commercial and residential installations.

Material & Properties

Material Composition

Mechanical Properties

Thermal & Corrosion Performance

Specifications

Parameter Specification Standard/Reference
Tube Outer Diameter (OD) 3.18 mm (1/8"), 6.35 mm (1/4"), 9.53 mm (3/8"), 12.70 mm (1/2") ASTM A269
Tube Wall Thickness 0.50 mm – 1.20 mm (0.020" – 0.047") ASTM A269 Table 3
Coil Winding Diameter 50 mm – 250 mm (2" – 10") Manufacturer specification
Coil Length per Spool 10 m – 100 m (33 ft – 328 ft) Custom order available
Fins per Inch (FPI) 10 FPI, 12 FPI, 14 FPI (when finned) ASHRAE Standard 15
Fin Material Aluminum (Al 1100) or Stainless Steel —
Pressure Rating ≤ 1.6 MPa (232 psi) operating; 2.4 MPa (348 psi) test EN 10217-7
Condensate Flow Capacity 0.5 – 8.0 L/min depending on coil size and AHU configuration ASHRAE Handbook – HVAC Systems
Drain Pipe Diameter (Recommended) 15 mm (1/2") minimum for single unit; 20 mm (3/4") for multi-unit manifolds ASHRAE 90.1; Local plumbing codes
Surface Roughness (Ra) 0.2 – 0.8 μm ISO 1302
Dimensional Tolerance ±0.05 mm (OD); ±0.02 mm (wall thickness) ASTM A213

Manufacturing Process

1. Raw Material Preparation

High-purity stainless steel wire rod (typically Grade 304 or 316L) is sourced from certified mills with full chemical composition documentation. Incoming material undergoes spectroscopic verification (OES analysis) to confirm alloy chemistry within specification limits.

2. Seamless Tube Forming

The coil tube is produced via the seamless drawing process:

  1. Piercing: Hot-rolled steel billets are pierced to create hollow blanks
  2. Reduction: Multiple passes through reduction mills achieve target OD and wall thickness
  3. Drawing: Cold drawing through precision dies ensures dimensional accuracy and improved surface finish
  4. Pilot Removal: Internal mandrel (pilot) is removed post-drawing for seamless internal bore

3. Annealing & Pickling

Tubes undergo solution annealing at 1,050–1,100 °C followed by controlled cooling to restore full austenitic structure and eliminate residual stresses from cold working. Subsequent acid pickling (HNO₃/HF mixture) removes oxide scale, establishing the passive chromium oxide film essential for corrosion resistance.

4. Coil Winding & Finning

Formed tubes are wound into precise helical coils using CNC-controlled winding machinery. When finned configurations are required, aluminum or stainless steel fins are mechanically bonded to the tube OD via a process that ensures thermal contact resistance below 0.001 m²·K/W.

5. Brazing & Assembly

Header connections are fabricated using phosphorus-copper brazing alloy (e.g., BAg-8) at 650–750 °C under nitrogen protection atmosphere. This ensures leak-tight joints compatible with the stainless steel substrate without galvanic degradation.

6. Hydrostatic Testing & Inspection

Each coil assembly undergoes 100% hydrostatic pressure testing at 1.5× operating pressure for a minimum dwell time of 30 seconds. Non-destructive testing (NDT) methods including dye penetrant inspection and, where applicable, eddy current testing are employed on random samples.

Applications

HVAC Fan Coil Units (Primary Application)

The coil tube is the core heat exchange element within fan coil units used in commercial buildings, hospitals, hotels, and residential HVAC systems. Proper coil tube design directly impacts:

Additional Applications

Quality Certifications & Standards Compliance

Unique Selling Points

Technical Notes on Condensate Management

The selection of appropriate coil tube specifications must be integrated with condensate drainage system design. Key engineering considerations include:

  1. Condensate Volume Calculation: Based on coil effective surface area, air-side heat transfer coefficient, dew point depression, and system operating conditions. Typical formula: Q_condensate = m_air × (ω_in − ω_out) × 3600, where ω represents humidity ratio.
  2. Drain Pipe Diameter Selection: Minimum 15 mm (1/2") for individual fan coil units handling up to 4.0 L/min condensate; upgrade to 20 mm (3/4") for flows exceeding 4.0 L/min or multi-unit header connections.
  3. Slope Requirements: Condensate drain lines must maintain a minimum slope of 0.5% (1:200) toward the discharge point to ensure gravity drainage without air locking.

Wenzhou Jixing Metal Materials Co., Ltd provides complete technical documentation and engineering support to ensure that coil tube selection, condensate prediction, and drainage design are harmonized for optimal system performance and long-term reliability.