Stainless Steel Coil Tube — Fan Coil Unit (FCU) Heat Exchanger Series

Product Overview

The Stainless Steel Coil Tube (Coiltube) manufactured by Wenzhou Jixing Metal Materials Co., Ltd. is a precision-engineered tubular product designed primarily for use in fan coil unit (Fan Coil Unit, FCU) heat exchangers and central air conditioning terminal systems. These coil tubes serve as the core heat transfer elements within HVAC (Heating, Ventilation, and Air Conditioning) end-unit devices, where they facilitate efficient thermal exchange between circulating refrigerant or chilled water and ambient air. The product is engineered to meet the demanding requirements of modern building climate control systems, offering superior corrosion resistance, thermal conductivity, and mechanical durability under continuous cyclic operation.

As a specialized component within the HVAC supply chain, the coil tube integrates seamlessly with intelligent controller systems that regulate airflow velocity, water valve actuation, and temperature setpoints — enabling precise energy management and occupant comfort optimization in commercial and industrial environments.

Material & Properties

The coil tubes are fabricated from high-grade austenitic stainless steel, selected for their exceptional combination of corrosion resistance, weldability, and thermal performance in aqueous and refrigerant environments.

Specifications

Parameter Specification Standard / Tolerance
Outer Diameter (OD) 6.35 mm (1/4"), 9.53 mm (3/8"), 12.70 mm (1/2"), 15.88 mm (5/8"), 19.05 mm (3/4") ±0.05 mm
Wall Thickness (WT) 0.50 mm – 1.50 mm ±0.025 mm
Coil Pitch (Center-to-Center Spacing) 7.0 mm – 12.0 mm (adjustable per heat exchanger design) ±0.10 mm
Tube Length per Row 300 mm – 1,200 mm (custom lengths available) ±0.5 mm
Number of Rows 2 – 6 rows (configurable) —
Bend Radius (Minimum) ≥ 3 × OD (to prevent wall thinning and ovality) —
Maximum Working Pressure 1.6 MPa (standard); 2.5 MPa (heavy-duty) Hydrostatic test at 1.5 × working pressure
Refrigerant Compatibility R-410A, R-32, R-134a, R-407C, water/glycol mixtures —
Flow Velocity (Nominal) 1.5 – 3.0 m/s (optimized for heat transfer coefficient) —
Heat Transfer Efficiency (U-value) 250 – 450 W/(m²·K) depending on configuration ASTM F2020 test methodology
Surface Roughness (Ra) ≤ 0.4 μm (electropolished); ≤ 0.8 μm (2B finish) ISO 4287
Standards Compliance ASTM A269/A270, EN 10216-5, GB/T 14976, ASME B31.5 —

Manufacturing Process

The production of precision stainless steel coil tubes follows a rigorous multi-stage manufacturing workflow to ensure dimensional accuracy, metallurgical integrity, and performance reliability:

  1. Raw Material Selection & Verification: Stainless steel strip or tube blanks are sourced from certified mills and subjected to spectrographic analysis (Optical Emission Spectrometry, OES) to verify chemical composition compliance with the specified grade. Mill test certificates (Mill Test Report, MTR) are retained for traceability.
  2. Coil Winding / Forming: Straight tubes are formed into helical coil configurations using CNC-controlled tube coiling machinery. The coiling process employs precision tooling and tension control to maintain uniform coil pitch and minimize residual stress. For fan coil unit heat exchangers, the tubes are typically formed into serpentine (hairpin) or continuous helical patterns depending on the exchanger design.
  3. Welding: Where tube connections are required (e.g., at headers or manifolds), automated orbital welding or TIG (Tungsten Inert Gas) welding is employed. The weld seam is protected by a high-purity argon (Ar) gas shield (≥ 99.99% purity) to prevent oxidation. Weld quality is verified through visual inspection and, where specified, radiographic testing (RT) or ultrasonic testing (UT) in accordance with ASME Section IX.
  4. Heat Treatment / Solution Annealing: Following forming and welding, tubes undergo solution annealing at 1,050–1,150°C followed by controlled cooling (air or water quench) to restore full austenitic microstructure, eliminate residual stresses, and maximize corrosion resistance. This step is critical for preventing sensitization and intergranular corrosion.
  5. Pickling & Passivation: The annealed tubes are subjected to acid pickling (typically a mixture of nitric acid HNO₃ and hydrofluoric acid HF) to remove oxide scale, followed by passivation treatment to form a stable chromium oxide (Cr₂O₃) passive film on the surface. This enhances long-term corrosion resistance.
  6. Surface Finishing: Optional electropolishing is performed using a controlled electrolytic process (typically 10–15% H₂SO₄ + 80–85% H₃PO₄) to achieve ultra-smooth surface roughness (Ra ≤ 0.4 μm), which reduces fouling and improves hygienic performance.
  7. Dimensional Inspection & Quality Control: Each batch undergoes comprehensive inspection including OD and wall thickness measurement (using ultrasonic thickness gauges or calibrated micrometers), coil pitch verification, hydrostatic pressure testing, and dimensional conformity checks against the engineering drawing. Non-destructive testing (NDT) methods include magnetic particle inspection (MPI) for surface defects and dye penetrant inspection (DPI) for weld integrity.
  8. Final Assembly & Packaging: Verified coil tube assemblies are cleaned, protected with corrosion-inhibitive packaging, and shipped with accompanying documentation including certificates of conformance, material test reports, and dimensional inspection records.

Applications

The stainless steel coil tube is a critical component across a wide spectrum of HVAC and thermal management systems:

Quality Certifications

Wenzhou Jixing Metal Materials Co., Ltd. maintains a comprehensive quality management framework to ensure product reliability and regulatory compliance:

Unique Selling Points

The stainless steel coil tube from Wenzhou Jixing Metal Materials Co., Ltd. distinguishes itself through several key differentiators:

Technical Notes

Proper installation and maintenance of the stainless steel coil tube heat exchanger assembly is essential for sustained performance. The following considerations should be observed: