Stainless Steel Coil Tube for Fan Coil Units — Anti-Freeze Grade

Product Overview

The Stainless Steel Coil Tube (Coiltube) produced by Wenzhou Jixing Metal Materials Co., Ltd. is a precision-engineered tubular product designed specifically for the coil assemblies within Fan Coil Units (FCUs) used in heating, ventilation, and air conditioning (HVAC) systems. This product addresses the critical challenge of freeze protection in northern regions where ambient temperatures can drop significantly below freezing during winter months. The coil tube serves as the core heat exchange element, facilitating efficient thermal transfer between circulating refrigerant or heating medium and the surrounding air stream.

Drawn from extensive industry experience regarding the anti-freezing challenges encountered in northern climates, this coil tube is engineered with material properties and geometric configurations that minimize the risk of freezing damage, ensuring reliable operation even under extreme cold conditions. The product represents a convergence of metallurgical expertise, thermal engineering, and practical field knowledge accumulated through real-world deployment scenarios.

Material & Properties

Base Material

The coil tube is manufactured from austenitic stainless steel, primarily conforming to ASTM A213 TP304 or ASTM A213 TP316 specifications. The TP316 grade incorporates molybdenum (Mo) content of 2.0–3.0% by weight, providing enhanced resistance to chloride-induced pitting and crevice corrosion — a critical advantage in humid environments where condensation accumulates on coil surfaces.

Key Material Properties

Anti-Freeze Design Characteristics

The austenitic stainless steel matrix exhibits a face-centered cubic (FCC) crystal structure that does not undergo a ductile-to-brittle transition at low temperatures. Unlike carbon steel alternatives, this coil tube maintains full toughness and formability even at sub-zero temperatures, eliminating the risk of catastrophic brittle fracture during freeze events. This intrinsic material property is the primary defense mechanism against the freeze damage problems documented in northern regional installations.

Specifications

Parameter Specification Standard / Reference
Outer Diameter (OD) 6.35 mm (1/4"), 9.53 mm (3/8"), 12.7 mm (1/2"), 15.88 mm (5/8"), 19.05 mm (3/4") ASTM B801 / EN 10217
Wall Thickness 0.3 mm – 1.5 mm (configurable) ASTM B619
Coil Length Up to 300 m per continuous coil (spool) —
Surface Finish No. 1 (hot-rolled), 2B (cold-rolled), BA (Bright Annealed), or Polished (Ra ≤ 0.4 μm) ASTM A480
Coil Winding Spiral-wound or serpentine-formed configurations —
Tube Pitch Configurable: 12 mm – 25 mm center-to-center ASHRAE Standard 15
Hydrostatic Test Pressure 1.5 × Maximum Operating Pressure (MOP) ASME B31.5
Maximum Operating Pressure Up to 2.5 MPa (362.5 psi) —
Refrigerant Compatibility R-410A, R-32, R-134a, R-407C, Ammonia (NH₃), Glycol solutions —
Heat Transfer Coefficient 1,800 – 2,500 W/(m²·K) (depending on flow velocity and configuration) —
Design Service Life ≥ 25 years in HVAC applications —
Freeze Resistance Operational integrity maintained down to −40°C ambient ISO 23946 (Cryogenic piping)

Manufacturing Process

1. Raw Material Selection and Milling

Virgin stainless steel wire rod or strip is sourced from certified mills (e.g., Outokumpu, POSCO, or domestic equivalents) with full chemical composition traceability. Incoming material undergoes spectroscopic verification (OES) to confirm compliance with specified grades.

2. Drawing and Cold Forming

The tube is cold-drawn through precision tungsten carbide dies to achieve dimensional tolerances within ±0.05 mm for outer diameter and ±10% for wall thickness. This cold-working process enhances surface finish and mechanical properties through work hardening.

3. Annealing and Pickling

Periodic solution annealing is performed at 1050°C – 1100°C in a controlled atmosphere (nitrogen or argon) to relieve residual stresses introduced during drawing. Subsequent pickling and passivation removes surface oxides and restores the passive chromium oxide film essential for corrosion resistance.

4. Coiling and Forming

The straight tube is mechanically formed into the required spiral or serpentine coil geometry using CNC-controlled coiling equipment. Forming parameters are optimized to prevent wall thinning beyond 15% of original thickness and to maintain consistent coil pitch throughout the assembly.

5. Brazing and Header Assembly

Tube ends are joined to inlet and outlet headers using phosphorus-free copper brazing alloys (e.g., BAg-19Cu per AWS A5.8) in a vacuum or inert gas atmosphere. This ensures contamination-free joints that maintain the full corrosion resistance of the stainless steel system.

6. Quality Inspection

Applications

Primary Applications

Anti-Freeze Application Context

In northern regions (particularly those with design temperatures below −20°C), conventional carbon steel coils in fan coil units are susceptible to freeze damage when heating circuits are inadvertently shut off or when glycol concentration falls below the protection threshold. The stainless steel coil tube's cryogenic toughness, combined with its low thermal expansion coefficient, provides a robust solution that withstands repeated freeze-thaw cycles without degradation of mechanical integrity or dimensional accuracy.

Quality Certifications

Unique Selling Points

Technical Notes for Northern Region Deployment

Recommendation: When deploying stainless steel coil tubes in fan coil units operating in northern climates, the following measures should be implemented in conjunction with the coil tube's inherent freeze resistance:

  • Maintain glycol solution concentration at or above 30% for design temperatures below −20°C
  • Install low-water-flow and freeze-stat protection devices upstream of the coil assembly
  • Ensure proper insulation of connecting piping to minimize heat loss and condensation formation
  • Implement seasonal commissioning protocols that verify coil integrity after each freeze-season cycle
  • Design coil configuration to allow complete drainage (drip-leg arrangement) to eliminate residual water that could freeze during shutdown