1. Product Overview

The Stainless Steel Coil Tube is a precision-engineered heat exchange component designed for integration into Fan Coil Units (FCUs) — the core terminal equipment in commercial and residential HVAC (Heating, Ventilation, and Air Conditioning) systems. This coil tube serves as the primary evaporator or condenser element within the FCU, facilitating efficient thermal transfer between the circulating chilled or heated water and the process air stream.

The fundamental engineering principle underlying this product centers on the dehumidification capacity of the FCU, which is directly and significantly governed by the average supply and return water temperature (Tavg = (Tsupply + Treturn) / 2). A lower average water temperature increases the temperature differential (ΔT) across the coil surface, thereby enhancing both sensible and latent heat transfer rates. This, in turn, maximizes the moisture removal capability (latent cooling load) of the unit, which is critical for maintaining indoor relative humidity (RH) within acceptable comfort ranges of 40–60% RH.

Key Engineering Insight: The dehumidification performance of a fan coil unit is nonlinearly dependent on the average supply/return water temperature. A reduction in Tavg by even 1–2 °C can result in a 15–30% increase in latent heat transfer capacity, provided the coil surface temperature remains below the dew point temperature of the incoming air. The stainless steel coil tube is engineered to maintain structural integrity and thermal efficiency across this critical operating range.

2. Material & Properties

The coil tube is manufactured from high-grade austenitic stainless steel, selected for its superior corrosion resistance, thermal conductivity, and long-term mechanical stability in humid, chemically aggressive environments typical of HVAC applications.

3. Technical Specifications

Parameter Specification Standard / Reference
Tube Outer Diameter (OD) 6.35 mm (1/4"), 9.52 mm (3/8"), 12.7 mm (1/2") ASTM A213
Tube Wall Thickness 0.50 mm – 1.00 mm ASME B36.19M
Tube Inner Diameter (ID) 5.35 mm – 11.70 mm (dependent on OD and wall thickness) —
Coil Pitch (Center-to-Center Spacing) 6.35 mm – 19.05 mm ASHRAE Handbook — HVAC Systems & Equipment
Number of Rows 2 rows – 8 rows (configurable) —
Fin Type Aluminum corrugated fins, louvered or micro-channel —
Fin Density 10 FPI – 18 FPI (Fins Per Inch) —
Maximum Operating Pressure 1.6 MPa (232 psi) — water circuit side EN 12828
Hydrostatic Test Pressure 2.4 MPa (348 psi) — 1.5× maximum operating pressure ISO 5149-2
Recommended Water Flow Velocity 0.5 m/s – 1.5 m/s ASHRAE Guideline 34
Heat Transfer Coefficient (Air Side) 25 – 55 W/(m²·K) ASHRAE Fundamentals
Heat Transfer Coefficient (Water Side) 2,500 – 5,000 W/(m²·K) ASHRAE Fundamentals
Overall Heat Transfer Coefficient (U-value) 60 – 120 W/(m²·K) (typical operating conditions) —
Dehumidification Capacity Range 10 – 85 g/h per kW of total cooling capacity ASHRAE Standard 90.1
Coil Length (Standard) 300 mm – 2,000 mm (custom lengths available) —
Coil Height (Standard) 250 mm – 750 mm —
Connection Type Flanged, threaded (G, BSP), or welded headers ISO 7-1 / BSPP

4. Manufacturing Process

The production of the stainless steel coil tube follows a rigorously controlled multi-stage manufacturing workflow to ensure dimensional accuracy, thermal performance, and long-term reliability:

  1. Raw Material Procurement & Inspection: Stainless steel tubes are sourced from certified mills and subjected to spectroscopic analysis (PMI — Positive Material Identification) to verify chemical composition compliance with ASTM/ASME grade requirements.
  2. Tube Cutting & End Preparation: Precision plasma or laser cutting to specified lengths; tube ends are deburred and chamfered to facilitate seamless insertion into headers.
  3. Tube Bending & Coil Forming: Cold-forming processes using CNC-controlled bending machines to achieve precise coil pitch and curvature radii without inducing work-hardening or micro-cracking in the tube walls.
  4. Fin Application: Aluminum fins are mechanically bonded to the stainless steel tubes using high-performance adhesive or crimping techniques, ensuring low thermal contact resistance at the fin-to-tube interface.
  5. Header Assembly & Brazing: Tubes are inserted into stainless steel or copper headers and sealed using phosphorus-free silver brazing alloy (e.g., BAg-25Cu) to maintain the corrosion resistance of the stainless steel system.
  6. Fin Stacking & Coil Assembly: Individual finned tube sections are assembled into the final coil stack with precise row and circuit configuration per design specifications.
  7. Hydrostatic Pressure Testing: Each completed coil is pressure-tested at 2.4 MPa for a minimum of 15 minutes to verify leak-tight integrity.
  8. Surface Finishing & Passivation: Final passivation treatment using citric acid or nitric acid solution to remove any free iron contamination and establish a protective chromium oxide layer on the exposed stainless steel surfaces.
  9. Performance Testing: Select coils undergo thermal performance verification in a climate chamber to validate heat transfer and dehumidification capacity against design targets.

5. Applications

The Stainless Steel Coil Tube for Fan Coil Units is deployed across a broad spectrum of HVAC applications where reliable, long-lasting, and high-performance heat exchange is essential:

6. Dehumidification Performance Analysis

The core technical differentiator of this coil tube product lies in its optimized design for latent heat transfer — the process by which moisture is condensed from the air stream. The following relationship governs the dehumidification capacity (Qlatent) of the FCU:

Qlatent ∝ (Tdew − Tsurface) × A × Uoverall

Where Tdew is the dew point temperature of the incoming air, Tsurface is the coil surface temperature (directly influenced by Tavg), A is the effective heat transfer area, and Uoverall is the overall heat transfer coefficient.

Key performance characteristics:

7. Quality Certifications & Standards Compliance

Wenzhou Jixing Metal Materials Co., Ltd. maintains rigorous quality management systems and holds the following certifications and standards compliance for this product line:

8. Unique Selling Points

9. Technical Recommendations

Design Note: To maximize the dehumidification capacity of fan coil units equipped with this stainless steel coil tube, engineers should design the chilled water system to maintain a supply water temperature of 6–7 °C (with a return temperature of 12–13 °C), yielding an average water temperature (Tavg) of approximately 9–10 °C. This operating range ensures the coil surface temperature remains sufficiently below the indoor air dew point to achieve optimal latent heat transfer while avoiding excessive supercooling that would result in unnecessary energy consumption.