Stainless Steel Coil Tube for Fan Coil Unit (FCU) Systems

Product Overview

The Stainless Steel Coil Tube is a precision-engineered heat exchange component specifically designed for integration into Fan Coil Unit (FCU) assemblies. As a core element of modern HVAC (Heating, Ventilation, and Air Conditioning) systems, the coil tube serves as the primary medium for thermal energy transfer between circulating refrigerant or hot water and ambient air. This product is manufactured by Wenzhou Jixing Metal Materials Co., Ltd., leveraging advanced metallurgical processing and geometric optimization to deliver superior thermal conductivity, structural integrity, and long-term corrosion resistance in demanding indoor climate control environments.

The coil tube design philosophy addresses the fundamental engineering challenge of maximizing heat transfer surface area within a compact volumetric footprint while maintaining low-flow resistance and mechanical robustness. The serpentine or spiral geometry of the coil tube is meticulously calibrated to achieve optimal Reynolds number (Re) regimes for turbulent flow conditions, thereby enhancing convective heat transfer coefficients.

Material and Properties

Base Material Specification

Key Mechanical and Thermal Properties

Unique Selling Points

Specifications

Parameter Specification Standard / Reference
Outer Diameter (OD) Φ6.35 mm (1/4"), Φ9.53 mm (3/8"), Φ12.70 mm (1/2") ASME B36.19M
Wall Thickness 0.50 mm – 1.65 mm (selected per pressure rating) ASTM A269 / A270
Coil Pitch (Center-to-Center Spacing) 12.7 mm (1/2"), 15.88 mm (5/8"), 19.05 mm (3/4") ASHRAE Handbook—HVAC Components
Number of Rows 1 to 6 rows (configurable per capacity requirement) ASHRAE 34 (Safety)
Fin Material Aluminum (1100-H14) or Copper-clad Aluminum; or Stainless Steel 304 fins ASTM B209
Fin Density (FPI) 8 – 14 fins per inch (Fins Per Inch) Industry Standard
Maximum Working Pressure 1.0 – 2.5 MPa (depending on wall thickness and OD) ASME BPV Code Section I
Hydrostatic Test Pressure 1.5× Maximum Working Pressure EN 12828 / ASME B31.5
Tube Length per Row 300 mm – 1500 mm (customizable) Project Specification
Overall Unit Dimensions 400 mm × 200 mm × 25 mm (standard module); scalable EN 15242
Refrigerant Compatibility R-410A, R-32, R-134a, R-407C, Ammonia (NH₃), CO₂ (R-744) ASHRAE 34 / ISO 817
Water Side Flow Rate 0.5 – 10.0 L/min (per module) ASHRAE 90.1
Heat Transfer Capacity 0.8 – 12.0 kW (per module, depending on configuration) EN 15242-1
Flow Resistance (Water Side) ≤ 30 kPa at rated flow rate Manufacturer's Data
Flow Resistance (Air Side) 50 – 120 Pa at 2.5 m/s face velocity ASHRAE Handbook

Manufacturing Process

Stage 1: Raw Material Preparation and Incoming Inspection

Stainless steel seamless tubes are procured from certified mills and subjected to incoming quality control including chemical composition analysis (via Optical Emission Spectrometry, OES), dimensional verification, and visual surface inspection. Material traceability is maintained through heat number documentation in accordance with ISO 9001 quality management system requirements.

Stage 2: Precision Cutting and Deburring

Tubes are cut to specified lengths using high-precision plasma or laser cutting systems with tolerance control of ±0.5 mm. Post-cutting deburring and chamfering operations ensure clean tube ends suitable for subsequent U-bend or header welding operations.

Stage 3: Coil Forming and Bending

The forming process involves precision bending of tubes into serpentine or spiral configurations using CNC-controlled mandrel bending machines. Critical process parameters include:

Stage 4: Fin Stamping and Insertion

Corrugated aluminum or stainless steel fins are precision-stamped to match tube OD dimensions and inserted into the formed coil at specified pitch intervals. Fin-to-tube contact is ensured through controlled expansion or crimping to minimize thermal contact resistance (target ≤ 0.0001 m²·K/W).

Stage 5: Brazing and Header Assembly

Tube ends are connected to inlet and outlet headers via vacuum brazing (for aluminum-fin configurations) or TIG welding (for all-stainless assemblies). Brazing is performed in a vacuum furnace at 620–650°C with vacuum levels ≤ 1×10⁻³ mbar to prevent oxidation and ensure full capillary joint penetration. For stainless-to-stainless joints, filler metals (ER308L or ER316L) are used with argon shielding gas (99.99% purity).

Stage 6: Pressure Testing and Leak Detection

Each coil tube assembly undergoes comprehensive testing:

Stage 7: Surface Treatment and Passivation

Post-welding passivation treatment using nitric acid (20% HNO₃) or citric acid (20% solution) removes welding heat-affected zone contamination and re-establishes the protective chromium oxide passive layer. Post-passivation rinse with deionized water and controlled drying to prevent water spot formation.

Stage 8: Final Quality Assurance and Packaging

Finished coil tubes undergo dimensional verification, performance testing (heat transfer capacity measurement per EN 15242 methodology), and final visual inspection. Each unit is serialized, documented with a Certificate of Conformance (CoC), and packaged with protective end caps and moisture-absorbing desiccants.

Applications

Primary Application: Fan Coil Units (FCU)

The stainless steel coil tube is the fundamental heat exchange element in Fan Coil Units deployed across commercial, residential, and industrial HVAC systems. Key application scenarios include:

Specialized Applications

Design Integration Considerations

When integrating coil tubes into FCU systems, the following design parameters must be carefully evaluated to ensure optimal system performance:

Heat Transfer Optimization: The effectiveness-NTU (Number of Transfer Units) method should be employed to determine required coil tube geometry for target thermal capacity. Fin efficiency (η_f) and overall surface efficiency (η_o) must be calculated considering fin spacing, tube layout, and air-side velocity profiles.

Pressure Drop Balance: Air-side and water-side pressure drops must be balanced to minimize fan and pump energy consumption while maintaining adequate flow rates. The Darcy-Weisbach equation and empirical correlations (e.g., Gnielinski correlation for tube-side heat transfer) provide the analytical framework.

Condensate Management: In cooling mode operation, coil tube surface temperatures below the dew point induce condensation. Drainage design, pan geometry, and anti-microbial surface treatments must be integrated to prevent moisture-related deterioration.

Quality Certifications and Standards Compliance

Product Certifications

Material Certifications

Performance Verification Standards

Documentation and Traceability

Each coil tube assembly is accompanied by comprehensive documentation including: