316L EP Capillary Coil Tube for IVD Analyzer Reagent Delivery Systems

Product Overview

The 316L EP (Electropolished) Capillary Coil Tube is a precision-engineered stainless steel tubing solution specifically designed for In Vitro Diagnostics (IVD) analyzers requiring critical reagent and sample transport at the microliter (μL) scale. Manufactured by Wenzhou Jixing Metal Materials Co., Ltd., this coil tube addresses the demanding requirements of modern automated laboratory analyzers, where minute volumes of reagents and biological samples must be delivered with absolute fidelity, zero cross-contamination, and minimal dead volume.

In contemporary IVD platforms—encompassing clinical chemistry analyzers, immunoassay systems, coagulation analyzers, and molecular diagnostics platforms—reagent tubing serves as the critical fluidic pathway connecting reagent reservoirs, sample injection ports, mixing chambers, and waste disposal systems. The integrity of this tubing directly determines assay accuracy, precision, and reliability. Any residual carryover, surface adsorption, or volumetric deviation introduced at the tubing level can propagate through the entire analytical workflow, resulting in erroneous diagnostic results.

This product line represents the pinnacle of microfluidic-grade stainless steel tubing technology, combining aerospace-grade material science with pharmaceutical-grade surface finishing to deliver a solution that meets the most stringent requirements of regulatory agencies including the U.S. Food and Drug Administration (FDA), European Medicines Agency (EMA), and China National Medical Products Administration (NMPA).

Material & Properties

Base Material: ASTM A270 / AMS 5510 316L Stainless Steel

The coil tube is fabricated from Type 316L austenitic stainless steel, a low-carbon variant of 316 stainless steel that is the gold standard material for biomedical and pharmaceutical fluid handling applications. The "L" designation denotes a maximum carbon content of 0.03% by weight, which significantly reduces the risk of intergranular corrosion during welding or heat treatment processes.

Chemical Composition (ASTM A270, Grade 316L)

Element Specification (%) Function
Carbon (C) ≤ 0.03 Prevents intergranular corrosion; ensures weld integrity
Chromium (Cr) 17.00 – 19.00 Forms passive oxide layer; primary corrosion resistance element
Nickel (Ni) 10.00 – 14.00 Stabilizes austenitic structure; enhances ductility and corrosion resistance
Molybdenum (Mo) 2.00 – 3.00 Provides superior pitting and crevice corrosion resistance; critical for chloride-containing biological fluids
Iron (Fe) Balance Base matrix element
Silicon (Si) ≤ 1.00 Improves high-temperature strength and oxidation resistance
Manganese (Mn) ≤ 2.00 Deoxidizer; enhances hot workability
Phosphorus (P) ≤ 0.045 Impurity control; prevents brittleness
Sulfur (S) ≤ 0.030 Impurity control; minimizes stress corrosion cracking susceptibility

Surface Finish: Electropolished (EP) — Ra ≤ 0.25 μm

The interior surface of the capillary tube undergoes a multi-stage electropolishing process that removes the outermost 3–10 micrometers of material through controlled anodic dissolution. This process achieves:

Key Material Properties

Property Value Relevance to IVD Application
Density 8.0 g/cm³ —
Tensile Strength (Annealed) ≥ 515 MPa (75,000 psi) Ensures mechanical integrity under peristaltic pump compression
Yield Strength (0.2% offset) ≥ 205 MPa (29,750 psi) Prevents permanent deformation during fluidic pressure cycling
Elongation ≥ 40% Ensures formability during coil winding without cracking
Thermal Conductivity 16.3 W/(m·K) at 20°C Facilitates thermal uniformity in temperature-controlled reagent zones
Corrosion Resistance Superior to 304 SS; resistant to chloride pitting Withstands aggressive biological reagents, cleaning solutions (NaOH, H₂O₂), and saline-based buffers
Biocompatibility ISO 10993 compliant Non-cytotoxic; suitable for contact with biological samples

Specifications

Geometric Dimensions

Parameter Specification Tolerance Notes
Outer Diameter (OD) 0.51 mm – 3.18 mm (0.020" – 0.125") ± 0.025 mm Custom diameters available; sub-millimeter ODs optimized for μL-scale flow
Wall Thickness 0.10 mm – 0.51 mm (0.004" – 0.020") ± 10% Thin-wall configurations minimize dead volume
Inner Diameter (ID) 0.31 mm – 2.16 mm (0.012" – 0.085") ± 0.025 mm Capillary-grade bore; roundness ≥ 95%
Coil Winding Diameter 25 mm – 150 mm (1.0" – 6.0") ± 0.5 mm Custom winding diameters to fit analyzer fluidic module footprints
Coil Length 500 mm – 10,000 mm (per coil) ± 2% Continuous lengths available; spliced assemblies with welded joints
Coil Pitch 1.0 mm – 5.0 mm ± 0.1 mm Consistent pitch prevents kinking and ensures uniform flow characteristics
Number of Turns 10 – 500 turns — Determined by required path length and spatial constraints

Flow Performance Characteristics

Parameter Specification Test Method
Dead Volume (per 100 mm tube length) ≤ 5 μL (for ID 0.51 mm); ≤ 50 μL (for ID 2.16 mm) Volumetric displacement method per ASTM F3145
Flow Rate Compatibility 0.1 μL/min – 500 μL/min Continuous flow with peristaltic or syringe pump
Maximum Operating Pressure 0.5 – 2.0 MPa (72 – 290 psi) Hydrostatic pressure test at 1.5× working pressure
Bubble-Free Flow Verified at ≤ 0.5 μL/min Visual inspection under magnification
Leak Rate ≤ 0.01 μL/min at 0.5 MPa Helium leak detection (ASTM F857)
Wetting Behavior Complete wetting; no meniscus pinning Contact angle measurement ≤ 10°

Surface & Contamination Control

Parameter Specification Test Method
Surface Roughness (Ra, Internal) ≤ 0.25 μm (standard); ≤ 0.10 μm (premium) White light interferometry / laser confocal profilometry
Surface Roughness (Rz, Internal) ≤ 1.0 μm (standard); ≤ 0.5 μm (premium) Profilometric measurement
Particulate Contamination ≤ 5 particles ≥ 5 μm per 100 mm length Laser particle counter (ASTM F2059)
Endotoxin Level ≤ 0.25 EU/mL (after rinse) LAL (Limulus Amebocyte Lysate) assay per USP <85>
Pyrogen Level Non-pyrogenic Rabbit pyrogen test (USP <151>)
Extractable Metals (1000 ppm limit) Pb, Cd, Hg, Cr, Ni, As — all below detection limit ICP-MS extraction test (GB/T 29761)
Protein Adsorption ≤ 0.1 μg/cm² (BSA model protein, 1 hour contact) UV absorbance method at 280 nm
Cell Adhesion Non-adherent; < 5% cell attachment rate Cell culture assay (fibroblast model)

Manufacturing Process

The production of 316L EP capillary coil tubes for IVD applications follows a rigorously controlled, multi-stage manufacturing process designed to ensure dimensional precision, surface integrity, and contamination control at every step.

Stage 1: Raw Material Selection & Certification

Stage 2: Cold Drawing & Precision Bore Formation

Stage 3: Annealing & Stress Relief

Stage 4: Coil Winding & Forming

Stage 5: Electropolishing (EP) — Interior Surface Treatment