316L EP Capillary Coil Tube for HPLC Mobile Phase Delivery Systems

Product Category: Stainless Steel Coil Tube — Instrumentation & Process Analysis

Application: High Performance Liquid Chromatography (HPLC) Mobile Phase Tubing

Product Overview

This precision-engineered 316L Electropolished (EP) Capillary Coil Tube is specifically designed for use as mobile phase delivery and transfer tubing in High Performance Liquid Chromatography (HPLC) systems. In HPLC analytical workflows, the mobile phase typically comprises a combination of organic solvents (e.g., acetonitrile, methanol, tetrahydrofuran) and aqueous buffer salts (e.g., phosphate, acetate, formate buffers). These chemically aggressive media pose significant challenges to tubing integrity, including corrosion, metal ion leaching, and surface contamination that can compromise analytical accuracy.

Conventional stainless steel tubing often suffers from trace metal ion release (Fe, Cr, Ni, Mo) into the mobile phase, leading to column contamination, detector interference, baseline noise elevation, and reduced column lifetime. This product addresses these critical issues through a combination of ultra-pure 316L base material, electropolishing surface treatment, and rigorous leachability validation, ensuring minimal metal ion contribution to the chromatographic system.

Material & Properties

Base Material: ASTM A269 / AMS 5510 316L Stainless Steel

Surface Treatment: Electropolishing (EP)

Key Material Properties

Specifications

Parameter Specification Standard / Test Method
Material Grade 316L (UNS S31603) ASTM A269 / AMS 5510
Surface Finish Electropolished (EP), Ra ≤ 0.25 µm ASTM A463
Outer Diameter (OD) Range 0.127 mm (1/32") to 3.175 mm (1/8") —
Wall Thickness Range 0.025 mm to 0.508 mm —
Coil Winding Diameter 10 mm to 200 mm (customizable) —
Coil Length Up to 50 meters per coil (standard) —
Pressure Rating (at 20°C) Up to 34.5 MPa (5000 psi) ASTM A269
Temperature Range −196°C to +450°C (continuous) —
Fe Leaching Rate ≤ 1 µg/L (in mobile phase, 24-hour immersion) ASTM F899
Cr Leaching Rate ≤ 0.5 µg/L (in mobile phase, 24-hour immersion) ASTM F899
Ni Leaching Rate ≤ 0.5 µg/L (in mobile phase, 24-hour immersion) ASTM F899
Mo Leaching Rate ≤ 0.3 µg/L (in mobile phase, 24-hour immersion) ASTM F899
Surface Roughness (Ra) ≤ 0.25 µm (ID & OD) ASTM A463
Passivation Post-EP passivation per ASTM A967 ASTM A967
Biocompatibility USP <661> / <665> compliant USP General Chapters
Winding Tolerance ±0.5 mm —
End Condition Flush-cut, burr-free (±0.01 mm chamfer) —

Manufacturing Process

Step 1: Raw Material Selection & Certification

Virgin 316L stainless steel bar stock or seamless tube is sourced from certified mill suppliers with full traceability documentation. Each heat lot is accompanied by a Mill Test Certificate (MTC) verifying chemical composition, mechanical properties, and purity. The carbon content is verified to be ≤ 0.03% to ensure resistance to sensitization during subsequent heat treatment cycles.

Step 2: Seamless Tube Forming

The selected grade is processed through hot-rolling, cold-drawing, and cold-drawing to final dimensions. For capillary-grade tubing (OD < 1 mm), multi-pass cold drawing through precision tungsten carbide dies ensures dimensional accuracy within ±0.005 mm tolerance on both ID and OD.

Step 3: Solution Annealing & Pickling

Tubing is solution-annealed at 1050–1100°C followed by controlled water quenching to achieve a fully austenitic, stress-free microstructure. Subsequent acid pickling (nitric/hydrofluoric acid blend) removes any oxide scale formed during annealing, restoring a clean, passive surface.

Step 4: Electropolishing (EP)

The core differentiating process involves controlled electrochemical dissolution using a phosphoric acid/sulfuric acid electrolyte at temperatures of 50–60°C. The process parameters (voltage, current density, time, temperature) are precisely controlled to achieve:

Step 5: Post-EP Passivation & Cleaning

Following electropolishing, tubing undergoes citric acid or nitric acid passivation per ASTM A967 to ensure a stable, protective chromium oxide passive film. Tubing is then cleaned using deionized water (≥ 18.2 MΩ·cm) and packaged in cleanroom conditions (ISO Class 7 or better) to prevent post-processing contamination.

Step 6: Precision Coiling & Winding

Tubing is wound into coils using CNC-controlled coiling machines that maintain constant winding tension and precise diameter control (±0.5 mm). Coiling is performed on mandrels with surface protection to prevent mechanical damage or scratches. Winding patterns (single-layer, multi-layer, figure-eight) are selected based on application requirements for pressure drop minimization and flow uniformity.

Step 7: Quality Inspection & Testing

Every production batch undergoes comprehensive testing:

Applications

Primary Application: HPLC Mobile Phase Delivery

This coil tube serves as the mobile phase transport line connecting solvent reservoirs to the HPLC pump, and as post-column transfer tubing between the detector and waste or fraction collector. In process analytical technology (PAT) applications, it is used for in-line monitoring loops and real-time quality control sampling lines.

Specific Use Cases:

  1. Pharmaceutical Process Analysis: In-line monitoring of critical quality attributes (CQAs) during bioprocess manufacturing, where metal ion contamination is unacceptable for product purity specifications
  2. Environmental Monitoring HPLC: Analysis of trace organic contaminants in water and soil samples, where ultra-low metal background is essential for detection limit compliance
  3. Food & Beverage Analysis: Quantification of additives, preservatives, and contaminants at ppm/ppb levels
  4. Clinical Laboratory Diagnostics: Therapeutic drug monitoring (TDM) and biomarker quantification requiring contamination-free sample handling
  5. Forensic & Toxicology: Analysis of trace drug residues where any metal contamination could interfere with mass spectrometry detection
  6. Process Analytical Technology (PAT): Real-time in-situ monitoring of reaction progress and endpoint determination in continuous manufacturing

Mobile Phase Compatibility Matrix:

Mobile Phase Component Concentration Range Compatibility
Acetonitrile (ACN) 0–100% Excellent
Methanol (MeOH) 0–100% Excellent
Tetrahydrofuran (THF) 0–100% Excellent
Dichloromethane (DCM) 0–100% Excellent
Phosphate Buffer 1–100 mM, pH 2–8 Excellent
Acetate Buffer 1–100 mM, pH 3–6 Excellent
Formate Buffer 1–100 mM, pH 2–5 Excellent
Triethylamine (TEA) 0.05–0.5% v/v Good (with periodic flushing)
NaCl (high concentration) > 500 mM Moderate (risk of pitting)

Quality Certifications & Compliance

Certification / Standard Scope Applicability
ISO 9001:2015 Quality Management System Full manufacturing process
ISO 13485:2016 Medical Device Quality Management Biocompatible applications
USP <661> Leachables Testing Pharmaceutical-grade tubing
USP <665> Extractables Testing Pharmaceutical-grade tubing
ASTM F899 Implantable Metallic Materials — Chemical Compositional Requirements Metal leaching limits
ASTM A269 Seamless Austenitic Stainless Steel Pipe and Tube Material specification
ASTM A463 Electropolished Stainless Steel Tubing Surface finish specification
ASTM A967 Passivation of Stainless Steel Parts Post-EP passivation
"Professional Coil Tubes, Professionally Made"
© 2026 Wenzhou Jixing Metal Materials Co., Ltd · This content is for technical reference only. Final order specifications are subject to the signed contract and mill test certificate.